Syntax {I,F,baud,word_length,stop_bits,parity,

flow_control p }

F1. F Communication Settings Packet
F2. baud Baud Rate. Options:
0 1200 1 2400
2 4800 3 9600 (default for all printers)
4 19200 5 38400
6 57600 (9850) 7 115200 (9850)
NOTE: The 9403 and 9805 printers do not support 38400
baud or greater. The 9820, 9830, 9835, and 9840
printers do not support 57600 baud or greater. Make
sure your host is capable of communicating at the
speed you select for the printer.
F3. word_length Word Length. Options:
07-bit word length
18-bit word length (default for all printer s)
F4. stop_bits Stop Bits. Options:
01-stop bit (default for all printers)
12-stop bits
F5. parity Parity. Options:
0None (default for all printers)
1ODD parity
2EVEN parity
F6. flow_control Flow Control. Options:
0None 2(CTS)
1DTR (default 3XON/XOFF
for all printers)
NOTE: If you use the DOS COPY command to download
your formats, set "Flow Control" to DTR (not
XON/XOFF).
Example {I,F,3,1,0,0,1 p }
Uses 9600 baud, an 8-bit word length, one stop bit, no parity, andthe DTR mode.Configuring the Printer 2-19