Syntax

{I,F,baud,word_length,stop_bits,parity,

 

flow_control p }

 

 

F1. F

Communication Settings Packet

 

F2. baud

Baud Rate. Options:

 

 

 

 

0

1200

1

2400

 

 

2

4800

3

9600 (default for all printers)

 

4

19200

5

38400

 

 

6

57600 (9850)

 

7

115200 (9850)

NOTE: The 9403 and 9805 printers do not support 38400 baud or greater. The 9820, 9830, 9835, and 9840 printers do not support 57600 baud or greater. Make sure your host is capable of communicating at the speed you select for the printer.

F3. word_length Word Length. Options:

07-bit word length

18-bit word length (default for all printers)

F4. stop_bits Stop Bits. Options:

01-stop bit (default for all printers)

1 2-stop bits

F5.

parity

Parity.

Options:

 

 

 

 

0

None (default for all printers)

 

 

1

ODD parity

 

 

 

 

2

EVEN parity

 

 

F6.

flow_control

Flow Control. Options:

 

 

 

 

0

None

2

(CTS)

 

 

1

DTR (default

3

XON/XOFF

 

 

 

for all printers)

 

 

NOTE: If you use the DOS COPY command to download your formats, set "Flow Control" to DTR (not XON/XOFF).

Example {I,F,3,1,0,0,1 p }

Uses 9600 baud, an 8-bit word length, one stop bit, no parity, and the DTR mode.

Configuring the Printer 2-19

Page 43
Image 43
Monarch 9830, 9835, 9805, 9820 manual Baud,wordlength,stopbits,parity, Flowcontrol p, DTR default, For all printers