1.Type the following format header, in any text editor:

{F,25,A,R,M,508,508,"FMT-25" p

2.Type the following constant text field:

C,250,80,0,1,1,1,W,C,0,0,"MONARCH MARKING:",0 p

3.Type the following bar code field:

B,1,12,F,110,115,1,2,120,5,L,0 p

4.Type the following text field:

T,2,18,V,30,30,1,1,1,1,B,C,0,0,0 p }

You have created a format packet for your MPCLII printer. Now, a batch packet must be created before you can print the format.

5.Type the following batch header, after the text field line:

{B,25,N,1 p

6.Type the following bar code data:

1,"12345678901" p

7.Type the following text field data:

2,"DAYTON, OHIO" p }

8.Save your file as SAMPLE.FMT.

9.Type MODE COM1:9600,N,8,1 at the DOS prompt if you are using serial communications. This sets the communication parameters at your host. These communication parameters must match those at your printer. See "Setting Communication Parameters," "Using Parallel Communications" in Chapter 2, or your host’s documentation for more information.

Getting Started 1-3

Page 15
Image 15
Monarch 9830, 9835, 9805, 9820 Type the following format header, in any text editor, Type the following constant text field