Also, keep in mind the following:

The Printer Applicators are released for 110-volt sales only.

You can use thermal direct printing (no ribbon) or thermal transfer printing (with ribbon).

The Printer Applicators do not support continuous (non-indexed) supplies.

P r i n t e r C o n f i g u r a t i o n I n f o r m a t i o n

The default configuration packet settings are:

{I,A,0,0,0,0,0 p

B,3,1,1,0,0 p

C,0,0,0,0,0,0 p

D,1,0,2 p

The supply type must be center aperture (3). Backfeed must be enabled (1). The dispense position and backfeed distances must be set to 95 dots when using 1/8-inch gap supplies.

E,{,,,", p ~,--,--,Od/Oa p

F,1,1,0,0,3 p

G,1,95,95 p }

S t a t u s P o l l i n g I n f o r m a t i o n

ENQ Response

Meaning

??Powerup

A@

Online/Ready to receive data after label

has been applied

 

 

 

C@

Label is printing

 

 

CH

Label is printed

 

 

SB

Out of supplies

 

 

SD

Out of ribbon

E-4Printer Differences

Page 274
Image 274
Monarch 9820, 9835 I n t e r C o n f i g u r a t i o n I n f o r m a t i o n, A t u s P o l l i n g I n f o r m a t i o n