Command

Parameter

 

 

^RB

Repeats the last printed batch, printing the same number of labels as

 

specified in the original batch. This command does not work if using batch

 

separators.

 

NOTE: Printer ignores this command if printing.

 

 

^RS

Resynchronizes supply when supply roll is changed.

 

NOTE: Printer ignores this command if printing.

^SD or

Disables the status polling feature by turning off the status polling control

^SCd

character. Sets the status polling control character to the ASCII value

 

given by the d parameter. The value of d can be any ASCII character.

^TP

Prints a test label set. NOTE: Printer ignores this command if printing.

 

 

The table represents the defined immediate command control character as ^ and the defined status polling control character as d. You may define these characters to suit your needs.

To use the immediate command control character or the status polling character within your data, use the tilde sequence.

C l e a r i n g P a c k e t s f r o m M e m o r y

You may want to remove packets from the printer to increase memory storage capacity or if the formats/fonts are no longer needed. In some cases, turning the printer off may clear the packets from memory. If not, send a format clear packet.

Syntax {header,packet#,action,device p }

1.header Identifies the packet. Options:

ACheck Digit Scheme

FFormat

GGraphic

WFont

2.packet# Identification number of the packet to clear (1-999) or font number (0-9999). 0 is for all fonts.

3. action

Enter C to clear the packet.

2-32Configuring the Printer

Page 56
Image 56
Monarch 9835 E a r i n g P a c k e t s f r o m M e m o r y, 32Configuring the Printer, Action Enter C to clear the packet