Status2

represents the MPCLII field that the error

B- Field Type

occurred on. If the packet has no fields,

 

Status2 A will be replicated. If the error

 

occurs before the field is identified a question

 

mark is sent. Since the batch data is

 

variable, a D is sent to indicate data.

Status2

represents the field number within each

C- Field Number

packet. The packet header is the first field

 

and each subsequent field is indicated by the

 

field separator.

Status2

represents the parameter within the field that

D- Parameter

the error occurred. The numbering begins

 

after the field identifier.

Status2

is the error that coincides with the error

E- Error Number

numbers presented in Chapter 8, "Diagnostics

 

and Errors."

"FMT-1/BCH-2"

The format or batch number is returned.

If more than one error occurred then only the most serious error will be acknowledged.

{J,"","F,B,4,6,33","FMT-1","BCH-2"}

Indicates that an error occurred on a bar code (B) field within a format (F) packet. The bar code field is the fourth (4) field in the packet. The error occurred in the sixth (6) parameter of the field. Error number 33 means the bar code density is invalid.

To clear an error, press CLEAR (ESCAPE/CLEAR) or ENTER (ENTER/PAUSE), depending on your printer. An ENQ can also clear errors numbered less than 500. Once the error is corrected, a job request can be sent. The printer cannot accept another job request until the error is resolved.

Status Polling 7-11

Page 163
Image 163
Monarch 9830, 9835, 9805, 9820 manual Field Number, Parameter, Error Number, FMT-1/BCH-2