Setting Switches and Jumpers

Hardware Preparation and Installation

 

 

2.5.2Setting Switches and Jumpers

Figure 2-2 on page 35 illustrates the placement of the switches, jumper headers, connectors and LED indicators on the CPCI-6115. Use this figure to help identify the approximate location of the jumpers on the CPCI-6115. There are seven manually configured headers on the baseboard. They are described in the following table:

Table 2-5 CPCI-6115 Jumper Map

Reference

Function

Comment

 

 

 

J6

Bus Mode Select

Jumper pins 1-2 for 60x mode

 

Header

Jumper pins 2-3 for MPX mode

 

 

 

J9

Stand-Alone Operation

Jumper pins 1-2 for Stand-Alone operation (no CPCI bus)

 

Header

 

 

 

 

J10

Flash Boot Bank Select

No jumper or jumper pins 1-2 for Bank A (32 MB)

 

Header

Jumper pins 2-3 for Bank B (8 MB)

 

 

 

 

 

J15

+/-12 V Present Header

Jumper pins 1-2 allows board operation without +/- 12 V

 

 

power

 

 

 

J20

Safe Start ENV Header

No jumper or jumper pins 1-2 for normal ENV settings

 

 

Jumper pins 2-3 for safe ENV settings

 

 

 

J25

SROM Initialization

Jumper pins 1-2 to enable SROM init

 

Enable Header

No jumper or jumper pins 2-3 to disable SROM init

 

 

 

 

 

J99

Flash Bank A Write

Jumper pins 1-2 to enable Bank A Flash Write

 

Protect Header

No jumper to disable Flash Writes

 

 

 

 

 

SW2

Manual Geographic

OFF (default) - GA from CompactPCI backplane

 

Address -

ON - generate address locally

 

 

 

 

 

Damage of the Product

Setting/resetting the switches during operation can cause damage of the product. Check and change switch settings before you install the product.