Hardware Preparation and Installation

Installing PMC Modules on the CPCI-6115

 

 

1.Attach an ESD strap to your wrist. Attach the other end of the ESD strap to the chassis as a ground. The ESD strap must be secured to your wrist and to ground throughout the procedure.

2.Remove chassis or system cover(s) as necessary for access to the board.

Personal Injury or Death

Dangerous voltages, capable of causing death, are present in this equipment. Use extreme caution when handling, testing and adjusting.

3.Carefully remove the CPCI-6115 from the card slot and lay it flat, with connectors J1 through J5 facing you.

4.Remove the PMC filler plate from the front panel of the CPCI-6115.

PMC Alignment

PMC Filler Plate

+3.3 V

+5 V

5.Set the PMC 2 voltage key to the desired position. (The PMC 1 I/O voltage key is factory-installed at the +5 V position since the IDE controller regulates +5 V I/O. Do not move the PMC 1 voltage key.)

44

CPCI-6115 CompactPCI Single Board Computer Installation and Use (6806800A68D)

Page 46
Image 46
Motorola CPCI-6115 manual Personal Injury or Death