NEC IP8800/S3600, IP8800/S6600, IP8800/S2400 Failure Analysis Method for Troubles on 10GBASE-R

Models: IP8800/S6700 IP8800/S3600 IP8800/S6600 IP8800/S6300 IP8800/S2400

1 250
Download 250 pages 34.34 Kb
Page 96
Image 96

3.Troubleshooting Functional Failures in Operation

2.Isolating the problem according to the failure analysis method

Isolate the problem according to the failure analysis method listed below.

Table 3-11: Failure Analysis Method for Troubles on 10GBASE-R

No.

 

Troubleshooting Steps

Problem

Action

 

 

 

 

 

1

According to the failure

Line quality on

Check the type of fiber optics. For the fiber optics type, see "Hardware

 

statistical information displayed

receiving side is

Installation Guide."

 

by the show interfaces

degraded.

 

 

 

 

Check the attenuation value if an optical attenuator is used. For the

 

command, check to see if the

 

 

 

 

 

optical level, see "Hardware Installation Guide."

 

statistical information below is

 

 

 

 

 

 

 

counted for the port.

 

 

Check the cable length. For the cable length, see "Hardware Installation

 

If counted, see "Problem" and

 

 

Guide."

 

"Action" columns.

 

 

 

 

 

 

Check to see if the cable is connected correctly. Check to see if end

 

Signal detect errors

 

 

 

 

 

surfaces of the cable are dirty. If they are dirty, remove the dirt.

 

LOS of sync

 

 

 

 

 

 

 

 

[IP8800/S6700]

 

 

Check to see if the transceiver is connected correctly.

 

 

[IP8800/S6600]

 

 

 

 

 

 

 

For the transceiver, follow the segment standard on the remote system.

 

 

[IP8800/S6300]

 

 

 

HI_BER

 

 

Check to see if the optical level is correct. For the optical level, see

 

 

[IP8800/S6700]

 

 

"Hardware Installation Guide."

 

 

[IP8800/S6600]

 

 

 

 

 

 

 

Perform the line test on this system and confirm that there is no problem

 

 

[IP8800/S6300]

 

 

 

LF

 

 

in the receiving function. See the execution results of the no test

 

 

[IP8800/S6700]

 

 

interfaces command and follow the indicated actions. For the test

 

 

[IP8800/S6600]

 

 

type to be specified, see "6.1 Testing Line."

 

 

[IP8800/S6300]

 

 

 

2

According to the receiving error

Line quality on

Check the type of fiber optics. For the fiber optics type, see "Hardware

 

statistical information displayed

receiving side is

Installation Guide."

 

by the show interfaces

degraded.

 

 

 

 

Check the attenuation value if an optical attenuator is used. For the

 

command, check to see if the

 

 

 

 

 

optical level, see "Hardware Installation Guide."

 

statistical information below is

 

 

 

 

 

 

 

counted for the port.

 

 

Check the cable length. For the cable length, see "Hardware Installation

 

If counted, see "Problem" and

 

 

Guide."

 

"Action" columns.

 

 

 

 

 

 

Check to see if the cable is connected correctly. Check to see if end

 

CRC errors

 

 

 

 

 

surfaces of the cable are dirty. If they are dirty, remove the dirt.

 

Symbol errors

 

 

 

 

 

 

 

 

 

Check to see if the transceiver is connected correctly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For the transceiver, follow the segment standard on the remote system.

 

 

 

 

 

 

 

 

 

 

 

Check to see if the optical level is correct. For the optical level, see

 

 

 

 

 

"Hardware Installation Guide."

 

 

 

 

 

 

 

 

 

 

 

Perform the line test on this system and confirm that there is no problem

 

 

 

 

 

in the receiving function. See the execution results of the no test

 

 

 

 

 

interfaces command and follow the indicated actions. For the test

 

 

 

 

 

type to be specified, see "6.1 Testing Line."

 

 

 

 

 

 

34

Page 96
Image 96