3. Troubleshooting Functional Failures in Operation

3.15.2Flow Sample Does Not Reach Collector

If problem still persists even after checking "3.15.1 sFlow Packets Do Not Reach Collector," check the following:

(1) Checking presence/absence of the relay packet

Execute the show interfaces command to check to see if the packet is relayed.

Figure 3-26: Display Example of Port Status

>show interfaces gigabitethernet 1/5 Date 2006/10/24 17:19:34 UTC

NIF1: active 48-port 10BASE-T/100BASE-TX/1000BASE-T

retry:0

Average:150Mbps/24Gbps

Peak:200Mbps at 15:44:37

 

Port5: active up

100BASE-TX full(auto)

0012.e220.ec31

Time-since-last-status-change:1:47:47

Average in:5Mbps

Bandwidth:10000kbps

Average out:5Mbps

Peak out:5Mbps at 15:44:36

Peak in:5Mbps at 15:44:18

Output

rate:

4893.5kbps

16.8kpps

 

Input

rate:

4893.5kbps

16.8kpps

 

Flow control send

:off

 

 

 

Flow control receive:off TPID:8100

:

>

Note: Confirm that the packet is relayed based on the display at underlined part.

(2) Checking settings of collector

Check to see if settings of the collector used are correct.

3.15.3Counter Sample Does Not Reach Collector

If problem still persists even after checking "3.15.1 sFlow Packets Do Not Reach Collector," check the following:

(1) Checking transmission interval of counter sample

Check to see if the transmission interval of the counter sample related to flow statistics is set to 0 in the configuration of this system. If set to 0, the counter sample data is not sent to the collector.

Figure 3-27: Display Example of Configuration

(config)# show sflow

sflow destination 192.1.1.1 6455 sflow sample 2048

sflow polling-interval 60

<- 0 must not be set here.

!

 

(config)#

 