NEC IP8800/S6300 Isolating Failures on External Power Unit, Isolating Failures on Power Module

Models: IP8800/S6700 IP8800/S3600 IP8800/S6600 IP8800/S6300 IP8800/S2400

1 250
Download 250 pages 34.34 Kb
Page 79
Image 79

2. Troubleshooting System Failures

2.2.2Isolating Failures on External Power Unit

If the external power unit fails, follow the steps below to isolate the failure.

Table 2-5: Isolating Failures on External Power Unit

No.

Failure

 

Action

 

 

 

1

POWER LED on the external power unit is lit in

Check LED on the power module mounted on the external power unit

 

green

and identify the power module that is not normally running. If the power

 

 

module is normally running, the states below are provided.

 

 

EPU-A:

 

 

 

DC-OK: Lit in green, DC-ALM: OFF

 

 

EPU-B:

 

 

 

DC-OK: Lit in green, DC-FAIL: OFF, AC-OK: Lit in green

 

 

For the power module that is not normally running, implement "Table

 

 

2-7: Isolating Failures on Power Module."

 

 

 

2

POWER LED on the external power unit is OFF

Follow the steps in "Table 2-6: Isolating Failures on External Power

 

 

Unit (Main Body)."

 

 

 

 

Table 2-6: Isolating Failures on External Power Unit (Main Body)

No.

Failure

 

Action

 

 

 

1

Power switch on the external power unit is OFF

Turn on the power switch.

 

 

 

 

2

Power cable of the external power unit is not

1.

Turn off the power switch.

 

correctly connected to the system

2.

Connect the power cable correctly.

 

 

3.

Turn on the power switch.

 

 

 

3

Input power to the external power unit is out of the

Ask the system administrator to take the action because of the failure on

 

range below

the power supply facility (i.e. not the failure on this system).

 

(AC power supply: 90 to 132V)

 

 

 

 

 

4

Other than 1 to 3 above

Replace the external power unit.

 

 

 

 

Table 2-7: Isolating Failures on Power Module

No.

Failure

 

Action

 

 

 

1

Power switch on the power module is OFF

Turn on the power switch on the power module.

 

 

 

 

2

Power cable of the power module is not correctly

1.

Turn off the power switch on the power module.

 

connected to the system

2.

Connect the power cable correctly.

 

 

3.

Turn on the power switch on the power module.

 

 

 

 

3

Power module is not correctly mounted on the

1.

Turn off the power switch.

 

external power unit

2.

Mount the power module correctly.

 

 

3.

Turn on the power switch.

 

 

 

4

Other than 1 to 3 above

Replace the power module.

 

 

 

 