NEC IP8800/S6600, IP8800/S3600, IP8800/S2400, IP8800/S6700 Check Items When Double-relay Continues

Models: IP8800/S6700 IP8800/S3600 IP8800/S6600 IP8800/S6300 IP8800/S2400

1 250
Download 250 pages 34.34 Kb
Page 150
Image 150

3.Troubleshooting Functional Failures in Operation

Table 3-47: Check Items When Double-relay Continues

No.

Troubleshooting Steps and Command

Action

 

 

 

1

Check the PIM neighboring information on the interface of the

If the neighboring router is not displayed, check the

 

network having multiple routers.

following:

 

show ipv6 pim neighbor

Confirm that PIM is running on the interface connected to

 

 

the neighboring router using the show ipv6 pim

 

 

command with "interface" parameter specified.

 

 

Confirm in the configuration that suppression of protocol

 

 

packet relay by filtering, etc. is not provided.

 

 

Verify the settings of the neighboring router.

 

 

 

88

Page 150
Image 150
NEC IP8800/S6600, IP8800/S3600 Check Items When Double-relay Continues, Troubleshooting Functional Failures in Operation