Chapter 2 Message List
486

iSM14412: Set Disk Array time : <aaa...a>, Disk

Array=<bbb...b>, status=<ccc...c>

[Classification] INFO
[Explanation] It indicates that the date and time in the Disk Array was set.
aaa...a : date, time. Example (Thu May 24 14:03:01 JST 2001)
bbb...b : Target disk array name
ccc...c : Execution state of the command.
good : Normal
failed(xxxx) : Error occurred (xxxx is error description)
[Measures] When an error occurs (status=failed was output), invalid date and time may be
set. Check the set values and execute again.

iSM14413: Rebuild(maintenance) : RANK=<aa>h,

PDN=<bb>h, PDG=<cc>h, Time=<dd>,

status=<eee...e>

[Classification] INFO
[Explanation] It indicates that rebuilding to specified physical disk has been started.
aa : RANK number
bb : Physical disk number
cc : PD group number
dd : Rebuild time
eee...e : Execution state of the command.
good : Normal
failed(xxxx) : Error occurred (xxxx is error description)
[Measures] When an error occurs (status=failed was output), the configuration or setting of
the disk array may be changed. After updating it to the newest information or
restarting state monitoring, check current state and execute again.