Property Management System - Communication Interface

Message Formats

Key -- Old room key status:

0 -- Key is in the key rack.

1 -- Key is not in the key rack.

New Extension -- New extension number. If the extension number is less than six digits, left justify the number and fill the remaining bytes with space (20H) characters.

Room Status 2 -- Room status of the new room. This flag is used in conjunction with the cleaning status flag to determine the status of the room.

Cleaning Status 2 -- Cleaning status of the new room. The possible combinations with room status are listed below:

Room

Clean

Status of the Room

1

0

Stay (Occupied)

1

1

Stay, Cleaning in progress

1

2

Stay, Cleaning ended

1

3

Stay, Inspected

Key -- New room key status:

0 -- Key is in the key rack.

1 -- Key is not in the key rack.

Provisional Check

In

0

1

2

3

4

6

8

9

15

16

02H

‘1’

‘!’

‘L’

‘5’ ‘6’

‘1’ ‘1’

‘7’

Extension 03H

xx

STX SA UA EI

FTC

MSC FC

6

ETX BCC

Figure 4-22 Provisional Check In

The only message field is the extension number that has been provisionally checked in. If the extension number is less than six digits, left justify the number and fill the remaining bytes with space (20H) characters. The room status is set to “Stay” (Room Status = ‘1’, Cleaning Status = ‘0’) and Room Cut-Off is cancelled.

NDA-30115 Revision 1.0

Page 51

Page 61
Image 61
NEC NDA-30115-001 manual Provisional Check, 02H ‘1’ ‘!’ ‘L’ ‘5’ ‘6’ ‘1’ ‘1’ ‘7’ Extension 03H