Property Management System - Communication Interface

Message Formats

Room Move/Swap/Copy (Model 60)

This message group is used exclusively by the Model 60 version. The Function

Codes are:

20-1 -- Room Move

20-2 -- Room Swap

20-5 -- Room Copy

Room Move leaves the second extension’s maid status unchanged, cancels the second extension’s Room Cut-Off and sets all other data to that of the first extension. The first extension’s maid status is set to ‘1’, Room Cut-Off is set, Do Not Disturb and Message Waiting is reset, Wake Up is cancelled, Language is set to ‘0’ and Guest Name and Group Number are cleared.

Room Swap completely exchanges the data between the first and second extensions.

Room Copy completely copies the data from the first extension to the second extension. The data for the first extension is unchanged.

0

1

2

3

4

6

8

9

15

21

22

02H

‘1’

‘!’

‘L’

‘2’ ‘0’

‘1’ ‘7’

**

First

Extension

Second Extension 03H

xx

STX SA UA EI

FTC

MSC FC

6

6

ETX BCC

** Multiple Function Codes use this message. See below.

Figure 4-35 Room Move/Swap/Copy

Message fields are:

FC-- There are three functions: (FTC-FC)

20-1 -- Room Move

20-2 -- Room Swap

20-5 -- Room Copy

First Extension -- This is the source extension number. If the extension number is less than six digits, left justify the number and fill the remaining bytes with space (20H) characters.

Second Extension -- This is the destination extension number. If the extension number is less than six digits, left justify the number and fill the remaining bytes with space (20H) characters.

NDA-30115 Revision 1.0

Page 63

Page 73
Image 73
NEC NDA-30115-001 manual Message fields are, Room Move/Swap/Copy