NDA-30115 Revision 1.0 Page 63
Property Management System - Communication Interface Message Formats
Room Move/Swap/Copy (Model 60)
This message group is used exclusively by the Model 60 version. The Function
Codes are:
20-1 -- Room Move
20-2 -- Room Swap
20-5 -- Room Copy
Room Move leaves the second extensions maid status unchanged, cancels the
second extensions Room Cut-Off and sets all other data to that of the fi rst
extension. The first extensions ma id status is set to 1, Room Cut-Off is set, Do
Not Disturb and Message Waiting is reset, Wake Up is cancelled, La ngua ge is set
to 0 and Guest Name and Group Number are cleared.
Room Swap completely exchanges the data between the first and second
extensions.
Room Copy completely copies the data from the first extension to the second
extension. The data for the first extension is unchanged.
Figure 4-35 Room Move/Swap/Copy

Message fields are:

FC-- There are three functions: (FTC-FC)
20-1 -- Room Move
20-2 -- Room Swap
20-5 -- Room Copy
First Extension -- This is the source extension number. If the extension number
is less than six digits, left justify th e number and fill the remaining bytes with
space (20H) characters.
Second Extension -- This is the destination extension number. If the extension
number is less than six digits, left justify th e number and f ill the remaini ng bytes
with space (20H) characters.

2’‘0’‘1’‘7** First Second

** Multiple Function Codes use this message. See below.

Extension Extension

01234 6 89 15 2122
STX SA UA EI FTC MSC FC 6 6
02H 1’‘!’‘L03H xx
ETX BCC