Message Formats

Property Management System - Communication Interface

Room Key Status

Change

0

1

2

3

4

6

8

9

15

16

17

02H

‘1’

‘!’

‘L’

‘6’ ‘1’ ‘1’ ‘2’

‘4’ Extension

Key

03H

xx

STX SA UA EI

FTC

MSC FC

6

1

ETX BCC

Figure 4-44 Room Key Status Change

Message fields are:

Extension -- Extension number. If the extension number is less than six digits, left justify the number and fill the remaining bytes with space (20H) characters.

Key -- Room key status:

0 -- Key is in the key rack.

1 -- Key is not in the key rack.

Extension Report

This message is used by the NEAX to notify the PMS of the addition of an extension to the system or a deletion of an extension from the system. Both the Model 60 and the Model 90 version use these messages. The two messages used are:

17-E -- Extension Delete Report

17-F -- Extension Assignment Report

Extension Delete

Report

0

1

2

3

4

6

8

9

15

17

18

02H

‘1’

‘!’

‘L’

‘1’ ‘7’ ‘1’ ‘3’

‘E’ Extension

Blank

03H

xx

STX SA UA EI

FTC

MSC FC

6

2

ETX BCC

Figure 4-45 Extension Delete Report

Message fields are:

Extension -- Extension number. If the extension number is less than six digits, left justify the number and fill the remaining bytes with space (20H) characters.

Blank -- Field contains two space (20H) characters.

Page 70

NDA-30115 Revision 1.0

Page 80
Image 80