Page 80 NDA-30115 Revision 1.0
Message Formats Property Management System - Communication Interface
Guest Room
Secretary
Telephone
Figure 4-51 Guest Room Secretary Telephone
The message fields are:
Boss -- Extension number of the boss. If the extension number is less than six
digits, left justify the number and fill the remaining bytes with space (20H)
characters.
Secty -- Extension number of the secretary. The secretarys extension is now
associated with the bosss extension. If the extension number is less than six
digits, left justify the number and fill the remaining bytes with space (20H)
characters.
Connecting Room
Figure 4-52 Connecting Room
The message fields are:
Master -- Extension number of the master extension. If the extension number is
less than six digits, left justify the n umber and fill the remaining bytes with
space (20H) characters.
Secondary -- Extension number of the secondary extension. The secondary
extension is now associated with the mas ter e x tensi on. If the e xtens ion number
is less than six digits, left justify the number and fill the remaining bytes with
space (20H) characters.
5’‘7’‘1’‘7’‘3Boss Secty
01234 6 89 15 2122
STX SA UA EI FTC MSC FC 6 6
02H 1’‘!’‘L03H xx
ETX BCC
5’‘7’‘1’‘7’‘4Master Secondary
01234 6 89 15 2122
STX SA UA EI FTC MSC FC 6 6
02H 1’‘!’‘L03H xx
ETX BCC