Property Management System - Communication Interface

Message Formats

Room Image Set 1

0

1

2

3

4

6

8

9

15

02H ‘1’

‘!’

‘L’

‘1’ ‘7’

‘2’ ‘8’

**

Extension

Vacancy

STX SA UA EI

FTC

MSC FC

6

1

16

17

18

32

33

Status

Code

Blank

03H

xx

1

1

14

ETX BCC

** Multiple Function Codes use this message. See below.

Figure 4-47 Room Image Set 1

The message fields are:

FC -- Function Codes that use this message format are: (FTC-FC)

17-1 -- Room Image Set 1 (Normal Request from PMS)

17-2 -- Room Image Set 1 (Normal Answer from NEAX)

17-3 -- Room Image Set 1 (Recovery Request from PMS)

17-4 -- Room Image Set 1 (Recovery Answer from NEAX)

Extension -- Extension number. If the extension number is less than six digits, left justify the number and fill the remaining bytes with space (20H) characters.

Vacancy -- Vacancy/Occupancy flag. The possible values are:

0 -- Vacant.

1 -- Occupied.

Status - Message Waiting status. The possible values are:

0 -- Message Waiting Lamp is off.

1 -- Message Waiting Lamp is on.

Code -- Restriction code for this extension. The possible codes are:

0 -- Do Not Disturb and Room Cut-Off are cancelled.

1 -- Room Cut-Off is set, Do Not Disturb is cancelled.

5 -- Do Not Disturb is set, Room Cut-Off is cancelled.

6 -- Do Not Disturb and Room Cut-Off are set.

Blank -- Field contains 14 space (20H) characters.