NEC NDA-30115-001 Connecting Room Set, 02H ‘1’ ‘!’ ‘L’ ‘6’ ‘2’ ‘1’ ‘7’ ‘3’ Master Secondary 03H

Models: NDA-30115-001

1 116
Download 116 pages 18.4 Kb
Page 95
Image 95

Property Management System - Communication Interface

Message Formats

Connecting Room

Set

0

1

2

3

4

6

8

9

15

21

22

02H

‘1’

‘!’

‘L’

‘6’ ‘2’

‘1’ ‘7’

‘3’

Master

Secondary 03H

xx

STX SA UA EI

FTC

MSC FC

6

6

ETX BCC

Figure 4-58 Connecting Room Set

The message fields are:

Master -- Extension number of the master extension. If the extension number is less than six digits, left justify the number and fill the remaining bytes with space (20H) characters.

Secondary -- Extension number of the secondary extension. The secondary extension is now associated with the master extension. If the extension number is less than six digits, left justify the number and fill the remaining bytes with space (20H) characters.

Connecting Room

Cancel

0

1

2

3

4

6

8

9

15

16

02H

‘1’

‘!’

‘L’

‘6’ ‘2’

‘1’ ‘1’

‘4’

Master

03H

xx

STX SA UA EI

FTC

MSC FC

6

ETX BCC

Figure 4-59 Connecting Room Cancel

The message fields are:

Master -- Extension number of the master extension. If the extension number is less than six digits, left justify the number and fill the remaining bytes with space (20H) characters.

NDA-30115 Revision 1.0

Page 85

Page 95
Image 95
NEC NDA-30115-001 Connecting Room Set, 02H ‘1’ ‘!’ ‘L’ ‘6’ ‘2’ ‘1’ ‘7’ ‘3’ Master Secondary 03H, Connecting Room Cancel