Property Management System - Communication Interface

Message Formats

Room Status

Change

0

1

2

3

4

6

8

9

15

02H

‘1’

‘!’

‘L’

‘6’ ‘1’ ‘1’ ‘3’

‘3’ Extension

Room Status

STX SA UA EI

FTC

MSC FC

6

1

16

17

18

 

 

 

 

 

 

 

 

 

Cleaning

Status

03H

xx

1 ETX BCC

Figure 4-43 Room Status Change

If Room Status is set to ‘0’ and Cleaning Status is set to either ‘3’ or ‘4’, the room data is cleared.

If Room Status is set to ‘0’ and the previous Room Status had been ‘1’ or ‘2’, Room Cut-Off is set and the Group registration is cancelled as in the case of a Check Out.

Message fields are:

Extension -- Extension number. If the extension number is less than six digits, left justify the number and fill the remaining bytes with space (20H) characters.

Room Status -- Room status. This flag is used in conjunction with the cleaning status flag to determine the status of the room.

Cleaning Status -- Cleaning status. The possible combinations with room status are listed below:

Room

Clean

Status of the Room

0

3

Vacant (Ready to sell)

1

0

Stay (Occupied)

1

1

Stay, Cleaning in progress

1

2

Stay, Cleaning ended

1

3

Stay, Inspected

2

0

Stay, Departure Day

2

1

Stay, Departure Day, Cleaning in progress

0

0

Out (Checked Out)

0

1

Out, Cleaning in progress

0

2

Out, Cleaning ended

0

4

Out of Order (Cannot sell)

NDA-30115 Revision 1.0