![](/images/backgrounds/113597/bg54.png)
Page 74 NDA-30115 Revision 1.0
Message Formats Property Management System - Communication Interface
Room Image Set 2
Figure 4-48 Room Image Set 2
The message fields are:
•FC -- Function Codes that use this message format are: (FTC-FC)
•17-5 -- Room Image Set 2 (Normal Request from PMS)
•17-6 -- Room Image Set 2 (Normal Answer from NEAX)
•17-7 -- Room Image Set 2 (Recovery Request from PMS)
•17-8 -- Room Image Set 2 (Recovery Answer from NEAX)
•Extension -- Extension number. If the extension number is less than six digits,
left justify the number and fill the remaining b ytes with s pace (20H) ch aracter s.
•Vacancy -- Vacancy/Occup an cy flag. The possible values are:
•0 -- Vacant.
•1 -- Occupied.
•Status - Message Waiting status. The possible values are:
•0 -- Message Waiting Lamp is off.
•1 -- Message Waiting Lamp is on.
•Code -- Restriction code for this exten sion. The possible codes are:
���0 -- Do Not Disturb and Room Cut-Off are cancelled.
•1 -- Room Cut-Off is set, Do Not Disturb is cancelled.
•5 -- Do Not Disturb is set, Room Cut-Off is cancelled.
•6 -- Do Not Disturb and Room Cut-Off are set.
Vacancy
Stay Reserve Language Cleaning
Wake UpWake Up
** Multiple Function Codes use this message. See below.
Status
Result
Status
Time
‘1’‘7’‘2’‘3’** Extension
01234 6 89 15 16
STXSAUAEIFTCMSCFC611
02H ‘1’‘!’‘L’
03H xx
ETX BCC
11111
17 18 19 20 21
Code
22 23 27 28
14