Property Management System - Communication Interface

Architecture

 

 

Table 2-5 Line Control Characteristics

 

 

 

 

 

 

 

Item

 

Conditions

 

 

 

 

 

 

 

Control Method

 

Contention method (point to point)

 

 

 

 

 

 

Operating Mode

 

Half duplex (if modems are used, set to full duplex)

 

 

 

 

 

 

Synchronization

 

Synchronous

 

 

 

 

 

 

 

Data Rate

 

4800 or 9600 bits/second (bps)

 

 

 

 

 

 

 

Frame Contents

 

EBCDIC

 

 

 

 

 

 

 

Error Control Method

 

CRC-16 (X16 + X15 + X2 + 1)

 

 

Bit Transmission Order

 

Priority is given to low order bits

 

 

 

 

 

 

Transmission Intervals

 

At each data generation. When a stream of information is

 

 

 

transmitted to the NEAX continuously, an interval of 0.5

 

 

 

seconds or more should be given between messages. Each

 

 

 

message must be delimited by the EOT code.

 

 

 

 

 

 

 

Priority Sequence

 

Primary office: NEAX

 

 

 

 

Secondary Office: PMS

 

 

 

 

 

 

 

Transfer Mode

 

Non-transparent mode

 

 

 

 

 

 

Message Composition

 

One message constitutes one record; SOH, ITB and ETB

 

 

 

are not used. Only the non-transparent mode is used.

 

 

 

 

 

Message Length

 

Variable length, maximum of 128 characters (including

 

 

 

STX and ETX).

 

 

 

 

 

 

 

Electrical Interface

 

RS-232C electrical standard interface

 

 

 

 

 

 

 

Signal Form

 

RS-404

 

 

 

 

 

 

 

Interface Distance

 

50 feet

 

 

 

 

 

 

 

Word Framing

 

10 bits or 11 bits

 

 

 

 

 

 

NDA-30115 Revision 1.0

Page 11

Page 21
Image 21