Message Formats

The format of all Data Link Maintenance messages are exactly as follows:

0

1

2

3

4

6

8

9

11

12

02H

‘1’

‘!’

‘L’

‘7’ ‘0’

‘0’ ‘7’

**

Blank

03H

xx

STX SA UA EI

FTC

MSC FC

2

ETX BCC

** Multiple Function Codes use this message. See below.

Figure 4-2 Data Link Maintenance Message Format

The message format breaks down as follows:

FC -- Function Codes that use this message format are: (FTC-FC)

70-0 -- Nop Test Normal Answer

70-2 -- Nop Test Recover Answer

70-3 -- Recovery Start Report

70-4 -- Recovery End Report

70-5 -- Data Link Release Request

70-6 -- Data Link Release Confirmation

70-8 -- Extension Number Request

70-F -- Nop Test

Blank -- Field consists of two space (20H) characters.

Maid Status

This message group uses multiple Feature Codes. The code pairs are as follows (first number is the Feature Code, second number is the Function Code):

11-1 -- Cleaning Start (Guest)

11-2 -- Cleaning End (Guest)

11-3 -- Inspection End (Guest)

11-4 -- Out of Order (Guest)

12-1 -- Cleaning Start (Administration)

12-2 -- Cleaning End (Administration)

12-3 -- Inspection End (Administration)

51-1 -- Guest Room 1 (Model 90)

51-2 -- Guest Room 2 (Model 90)

51-3 -- Guest Room 3 (Model 90)

51-4 -- Guest Room 4 (Model 90)

51-5 -- Guest Room 5 (Model 90)

51-6 -- Guest Room 6 (Model 90)