Property Management System - Communication Interface Message Formats
Extension
Assignment
Report
Figure 4-46 Extension Assignment Report
Message fields are:
•Extension -- Extension number. If the extension number is less than six digits,
left justify the number and fill the remaining b ytes with s pace (20H) ch aracter s.
•Def -- Defines the extension to be either an administr ation ex tensi on or a gues t
extension. Codes are:
•0 -- Administration
•1 -- Guest
•Class -- The room class designate d at the time of extension assignment.
‘1’‘7’‘1’‘3’‘F’Extension Def
Class
01234 6 89 15
STX SA UA EI FTC MSC FC 6 1
02H ‘1’‘!’‘L’
03H xx
ETX BCC1
16 17 18