Table 2-9 Retransmission Counts

 

 

 

 

 

 

 

Meaning

Count

 

 

 

 

 

 

 

The number of retransmissions of the start sequence when there is no

7

 

answer after transmitting the start sequence.

 

 

 

 

 

The number of retransmissions of the start sequence when NAK is

7

 

received after transmitting the start sequence.

 

 

 

 

 

The number of transmitting ENQs when WACK is received after the

15

 

transmission of an information block

 

 

 

 

 

The number of transmitting ENQs when there is no answer after the

7

 

transmission of an information block. (3 second intervals)

 

 

 

 

 

Timer Values

Table 2-10 Timer Values

Party

Starting Condition

Timer value

(seconds)

 

 

 

 

 

 

 

 

NEAX

Waiting for a start sequence answer.

1

 

 

 

 

Waiting for STX after transmitting the start sequence ACK.

20

 

 

 

 

Waiting for data reception complete (waiting for ETX, CRC).

20

 

 

 

 

Waiting for an answer after the transmission of a message.

1

 

 

 

PMS

Waiting for a start sequence answer.

3

 

 

 

 

Waiting for STX after transmitting the start sequence ACK.

25

 

 

 

 

Waiting for data reception complete (waiting for ETX, CRC).

25

 

 

 

 

Waiting for an answer after the transmission of a message.

3

 

 

 