Page 56 NDA-30115 Revision 1.0
Message Formats Property Management System - Communication Interface
Wake U p Se ttin g
(PMS)
Figure 4-28 Wake Up Setting (PMS)
Message fields are:
•Extension -- Extension number. If the extension number is less than six digits,
left justify the number and fill the remaining b ytes with s pace (20H) ch aracter s.
•Time -- Time for which a wake up call is set. Format used is HHMM using
military time.
•Source -- Code for the source of the wake up setting. Possible values are:
•1 -- Guest Extension.
•2 -- Attendant.
•3 -- Administration Extension.
•4 -- Property Management System.
01234 6 89 15
STX SA UA EI FTC MSC FC 6 4
02H ‘1’‘!’‘L’
03H xx
ETX BCC1
19 20 21
‘1’‘9’‘1’‘6’‘4’Extension Time
Source