Property Management System - Communication Interface

Message Formats

Guest Room

0

1

2

3

4

6

8

9

15

02H

‘1’

‘!’

‘L’

‘5’ ‘1’

‘2’ ‘3’

** Extension

Maid

STX SA UA EI

FTC

 

MSC FC

6

6

21

 

27

28

 

 

LEN

03H

xx

6ETX BCC

**Multiple Function Codes use this message. See below.

Figure 4-4 Guest Room (General)

Message fields are:

FC -- Function Codes that use this message format are: (FTC-FC)

51-1 -- Guest Room 1 (Model 90)

51-2 -- Guest Room 2 (Model 90)

51-3 -- Guest Room 3 (Model 90)

51-4 -- Guest Room 4 (Model 90)

51-5 -- Guest Room 5 (Model 90)

51-6 -- Guest Room 6 (Model 90)

51-7 -- Guest Room 7 (Model 90)

Note: This message was not previously defined in NEAX2400 IMS Hotel System PMS Interface Specification.

Extension -- Extension number. If the extension number is less than six digits, left justify the number and fill the remaining bytes with space (20H) characters.

Maid -- Identification number of the maid. If the maid identification number is less than six digits, left justify the number and fill the remaining bytes with space (20H) characters.

LEN -- Line Equipment Number.

NDA-30115 Revision 1.0