NETGEAR 700 Series manual Configure, Cos-Pvid

Models: 700 Series

1 152
Download 152 pages 41.65 Kb
Page 102
Image 102

700 Series Managed Switch User’s Guide for Software v2.1

<VLAN index #> = The VLAN ID. Adding the VLAN ID to the show vlan command displays the port that belongs to that particular VLAN. For example, show vlan 1 displays the ports that belong to VLAN 1.

An example of the display output is shown below:. Untagged port members: 4,5,7,11-15,19-23 Tagged port members: none

COS-PVID

The show vlan cos-pviddisplays the PVIDs and the CoS settings of each port.

Syntax

FSM726# show vlan cos-pvid

An example of the display output is shown below:

Port

PVID Priority

------------------------

1:1

1

Normal

1:2

1

Normal

1:3

1

Normal

1:4

1

Normal

1:5

1

Normal

Configure

Entering the command configure at the root prompt takes you into configuration mode. When you’re in configuration mode, the prompt changes to

FSM726(config)#

It is in this mode where the vast majority of configuration is performed. To exit the configuration mode and return to root prompt, use the exit command.

DiffServ

DiffServ divides traffic into one of 64 classes using the packet’s DSCP value. This allows for greater differentiation of traffic priority than port-based traffic prioritization.

Syntax

6-12

Command Line Interface

SM-10004-02

Page 102
Image 102