Network Technologies ST-xU operation manual Format RU Aacr

Models: ST-xU

1 42
Download 42 pages 18.35 Kb
Page 35
Image 35

NTI NODEMUX SERIES UNIVERSAL KVM SWITCH

CA - change all output channels

FORMAT:

CA AA,XX<CR>

 

CA = "change all outputs" command followed by at least one space

 

AA = unit address

 

XX = input /CPU to connect to all outputs/USERS

RESPONSE:

*<CR> (command received and executed OK)

 

?<CR> (syntax or transmission error occurred)

FYI: In this NODEMUX switch, this command will have the same effect as the CS command above.

RO - read single USER channel

FORMAT:

RO AA,YY<CR>

 

RO = "read output" command followed by at least one space

 

AA = unit address

 

YY = output/USER to read

RESPONSE:

*<CR> (command received and executed OK)

 

XX<CR> (XX = input/CPU connected)

 

-OR-

 

?<CR> (syntax or transmission error occurred)

RU - read unit size

FORMAT:

RU AA<CR>

 

RU = "read unit size" command followed by at least one space

 

AA = unit address

RESPONSE:

*<CR> (command received and executed OK)

 

XX,YY<CR> (XX = # of CPU’s, YY = # of USERS)

 

-OR-

 

?<CR> (syntax or transmission error occurred)

RV- read unit software version

FORMAT:

RV XX,00

RV= "read software version" command followed by at least one space AA= unit address

00= command for the address location in memory of the software version

RESPONSE:

-OR-

?<CR> (syntax or transmission error occurred)

CF - reset all connected units, regardless of address, to factory default configuration settings

WARNING: THIS COMMAND WILL RESET ALL RS232 DAISY CHAIN CONNECTED NODEMUX SWITCHES TO FACTORY DEFAULT SETTINGS. IF OTHER SWITCHES ARE DAISY CHAINED VIA RS232, DISCONNECT THEM BEFORE SENDING THIS COMMAND.

FORMAT:

CF 00

RESPONSE: (After 10-20 seconds)

COMMAND OK

RESET SWITCH CONFIGURATION IS COMPLETE

PLEASE RESET SWITCH POWER

FOR CHANGES TO TAKE EFFECT

31

Page 35
Image 35
Network Technologies ST-xU operation manual Format RU Aacr