INSTRUCTIONS FOR USE

ENGLISH

Problem

Possible cause

Remedy

3RD BROOM ARM

 

 

The 3rd broom arm does not lift/lower

The control valve assembly is stuck

Repair

 

The cylinder gaskets are worn

Overhaul the cylinder

 

The fuse is blown

Replace

 

Open lowering push-button

Replace

 

Open lifting push-button

Replace

 

The relay is burnt

Replace

 

The solenoid valve is burnt

Replace

SUCTION FAN

 

 

The suction fan is noisy

Not-lubricated fan bearings

Lubricate

 

Worn fan bearings

Replace

 

The motor is faulty

Repair

The suction fan turns but it is not efficient

The dust filters are clogged

Clean

 

The suction pipe is clogged

Clean

 

The suction pipe is cut/torn

Replace

 

The gasket between the suction inlet and the

Replace/adjust

 

hopper is broken or misadjusted (replace or

 

 

adjust)

 

 

There is no pressure at the suction system

Adjust the pump pressure

 

motor

 

The suction fan does not turn

The control valve assembly is stuck

Repair

 

The motor is faulty

Replace

 

Pump failure

Replace

SUCTION INLET AND SKIRT

 

 

The suction inlet does not collect debris

The suction inlet position is incorrect

Check the suction inlet and skirt height and

efficiently

 

operation

The suction inlet does not lift

Open electrical contact

Repair the electrical system

 

The control valve assembly is stuck

Repair

 

The cylinder gaskets are worn

Overhaul the cylinder

 

There is no pressure at the hydraulic system

Check the pump pressure

 

The fuse is blown

Replace

 

Open lifting push-button

Replace

 

Open joystick safety push-button

Replace

 

Relay board failure

Overhaul

 

The solenoid valve is burnt

Replace

SUCTION INLET AND SKIRT

 

 

The suction inlet does not lower

The suction fan is off

Activate

 

There is no pressure at the parachute valve

Check the suction fan control valve assembly

 

 

pressure

 

Lack of pressure in the control valve assembly

Check the pressure

 

solenoid valve

 

 

The fuse is blown

Replace

 

Deactivated broom switch

Activate

 

Open lowering push-button

Replace

 

Open joystick safety push-button

Replace

 

Relay board failure

Overhaul

 

The solenoid valve is burnt

Replace

The suction inlet does not shift sideways

Lack of pressure in the cylinder because of

Overhaul the cylinder

 

worn gaskets

 

 

The fuse is blown

Replace

 

Open left shifting push-button

Replace

 

Open right shifting push-button

Replace

 

Open safety push-button

Replace

 

Relay board failure

Replace

 

The solenoid valve is burnt

Replace

The skirt opening force is not sufficient

The skirt opening pressure is incorrect

Adjust the opening pressure

The skirt does not open/close

Deactivated push-button

Activate

 

The solenoid valve is burnt

Replace

RS 1300

33015124(3)2008-02

47

Page 69
Image 69
Nilfisk-Advance America RS 1300 manual Suction FAN, Suction Inlet and Skirt