ENGLISH
INSTRUCTIONS FOR USE
FUSE REPLACEMENT
1.Engage the parking brake (13, Fig. E).
2.Turn off the engine, by turning the ignition key (24, Fig. D) counterclockwise, to the end of stroke, then remove it.
3.Remove the electrical components protection panel (19, Fig. E) and then the transparent cover of the fuse box (3, 8, 9, Fig. E). Then replace the relevant fuse among the following:
Fuse box (3, Fig. E)
1.Choke system fuse (7.5 A)
2.Skirt solenoid valve fuse (10 A)
3.Skirt
4.Optional equipment fuse (10 A)
5.Blower fuse (20 A)
6.Fuel solenoid valve fuse (7.5 A)
7.Broom safety fuse (15 A)
8.Water pump fuse (15 A)
Fuse box (8, Fig. E)
1.Climate control system blower fuse (20 A)
2.Climate control system fuse (15 A)
3.Windscreen wiper fuse (10 A)
4.Flashing light fuse (7.5 A)
5.Glow plug control unit fuse (7.5 A)
6.Meter fuse (7.5 A)
7.Reverse gear buzzer fuse (7.5 A)
8.Open hopper/lid warning light fuse (7.5 A)
Fuse box (9, Fig. E)
1.Left side running light fuse (7.5 A)
2.Right side running light fuse (7.5 A)
3.Low beam fuse (10 A)
4.High beam fuse (15 A)
5.Brake light fuse (7.5 A)
6.Horn fuse (7.5 A)
7.Hazard warning lights/cab light fuse (10 A)
8.Turn signal fuse (7.5 A)
9.Glow plug fuse (80 A)
4.Install the fuse box transparent cover.
SUCTION INLET DISASSEMBLY/ASSEMBLY
NOTE
This is a basic procedure, it is often recalled during other procedures, when necessary.
Disassembly
1.Remove the side brooms (see the procedure in the relevant paragraph).
2.Move the 3rd broom (21, Fig. G) aside, and lower the suction inlet (17) according to the procedure shown in the relevant paragraph.
3.Engage the parking brake (13, Fig. E).
4.Turn off the engine, by turning the ignition key (24, Fig. D) counterclockwise, to the end of stroke, then remove it.
5.Mark the position of the pipes (1 and 2, Fig. AY) (for proper assembly), then disconnect them from the suction inlet (3) and plug them.
6.Mark the position of the pipes (4 and 5, Fig. AY) (for proper assembly), then disconnect them from the suction inlet (3) and plug them.
7.Disconnect the dust control system pipes (6 and 7, Fig. AY).
8.Disconnect the electrical connectors (8 and 9, Fig. AY) and remove the gasket.
9.Remove the screws (10, Fig. AY).
10.Move the suction inlet (3, Fig. AY) forward, and loosen the suction pipe clamp (11).
11.Disconnect the suction pipe (12, Fig. AY) from the suction inlet.
12.On both sides of the suction inlet, unscrew the nuts (13, Fig. AY) and disconnect the relevant springs.
13.Remove the suction inlet (3).
14.Collect the pipes (15, Fig. AY) disconnected from the suction inlet, and secure them with clamps (14). Fit a dust boot to prevent dirt and foreign material from entering the pipes (15).
Assembly
15.Assemble the components in the reverse order of disassembly.
16.If necessary, check the suction inlet and skirt height and operation (see the procedure in the relevant paragraph).
44
33015124(3)2008-02
RS 1300