Opening a Switch 11

Troubleshooting the Opening of a Switch

Errors can occur during the opening of a switch. If an error occurs, ASEM displays an error message. This message is illustrated in "Connection Error Message" (page 11).

Connection Error Message

If this message is displayed, the following items should be checked:

In slower networks, increase the Retry Count and Timeout values on the Properties screen. See "Setting ASEM Properties" (page 5) for information on performing this task.

In the Open Device screen, ensure that the correct read and write community strings have been entered for SNMP version 1 and 2 connections. See "Opening a Switch Using SNMP versions 1 or 2" (page 8) for more information on performing this task.

In the Open Device screen, ensure that the correct SNMP version 3 information has been entered for SNMP version 3 connections. See "Opening a Switch using SNMPv3" (page 10) for more information on performing this task.

Ensure that the switch is physically connected to the network.

Ensure that the switch is turned on and receiving power.

Ensure that the switch has been assigned a correct IP address.

Ensure that the correct IP address is being used in the Open Device screen.

Ensure that the problem does not exist because of an unrelated network misconfiguration.

Ensure that SNMP access is enabled on the switch. Refer Nortel Application Switch Operating System 24.0 Command Reference (NN47220-105) for information on enabling SNMP access.

Ensure that switch is not blocking access from the client IP address.

Connecting to a ASEM Server

When connecting to a switch through the ASEM, the user also has the option of connecting to an ASEM Server. To connect to a ASEM Server, follow this procedure:

Nortel Application Switch Element Manager

Users Guide

NN47220-101 (320512-D) 01.01 Standard

5.0 28 January 2008

Copyright © 2008, Nortel Networks

Page 11
Image 11
Nortel Networks NN47220-101 Troubleshooting the Opening of a Switch, Connecting to a Asem Server, Connection Error Message