TROUBLESHOOTING AND MAINTENANCE

4 Close the front cover and side cover.

Make sure that the misfeed message is cleared.

B:Misfeed in the fusing area

1Open the bypass tray and the side cover.

5 If you were unable to remove the misfeed in step 4, press down on the fusing unit paper guide knob to open the paper guide, and carefully remove the misfed paper.

2 Press and pull it open gently on both sides of the front cover.

Caution

• Do not touch the photoconductive drum

(green portion) when removing the misfed

5

paper. Doing so may damage the drum

 

and cause smudges on copies.

 

Take care not to let unfixed toner on the misfed paper soil your hands or clothes.

3 Turn the roller rotating knob in the direction of the arrow.

Roller rotating knob

4 Lift the fusing unit release levers and carefully remove the misfed paper.

Fusing unit release levers

6 Close the fusing unit paper guide and press down on the fusing unit release levers.

7 Close the front cover and side cover.

Make sure that the misfeed message is cleared.

Warning

The fusing unit is hot. Do not touch the fusing unit when removing misfed paper. Doing so may cause a burn or injury.