ENVIRONMENTAL

Operating Conditions:

See PERFORMANCE.

Approvals:

CE, UL, cUL

EMI Susceptibility:

Certified to EN50082-1:1992 and

 

EN50082-2:1995.

 

NOTE: For line-conducted disturbances

 

induced by RF fields (10V 80% AM 1kHz),

 

the product is self-recoverable in the

 

frequency bands 17 - 47MHz and 68 -

 

80MHz.

EMI Emissions:

Certified to EN50081-1:1992 and

 

EN50081-2:1994.

Safety Considerations:

Complies with EN61010-1:1993.

Supply Voltage:

90 - 264V AC 50/60Hz (standard)

 

20 - 50V AC 50/60Hz or 22 - 65V DC

 

(option)

Power Consumption:

4 watts approximately.

Front Panel Sealing:

To IP66 (NEMA 4).

PHYSICAL

 

Dimensions:

Depth - 110mm

Front Panel:

Width - 48mm, Height - 48mm (1/16 DIN)

Mounting:

Plug-in with panel mounting fixing strap.

 

Panel cut-out 45mm x 45mm.

Terminals:

Screw type (combination head).

Weight:

0.21kg maximum