SPECIFICATIONS
Amplifier Section | HCCA25001 | HCCA50001 | |
Power Output 4Ω (Watts | 750 x 1 | 1500 x 1 | |
rms) * | |||
|
| ||
Power Output 2Ω (Watts | 1500 x 1 | 3000 x 1 | |
rms) ** | |||
|
| ||
Power Output 1Ω (Watts | 2500 x 1 | 5000 x 1 | |
rms) | |||
|
| ||
Amplifier Efficiency | > 60% into 1Ω load at | > 60% into 1Ω load at | |
max. power | max. power | ||
| |||
|
|
| |
Signal to Noise ratio at |
|
| |
rated output power and | >100 dB | >100 dB | |
lowest impedance |
|
| |
Externally Bridgeable | No | No | |
|
|
| |
Remote Gain Function | yes (RGC2 supplied) | yes (RGC2 supplied) | |
|
|
| |
Distortion at Rated Power | 0.2% THD+N | 0.2% THD+N | |
|
|
| |
Frequency Response | 20Hz to 300Hz | 20Hz to 300Hz | |
±2.5dB | ±2.5dB | ||
| |||
|
|
| |
Linear Bandwidth | 20Hz to 300Hz | 20Hz to 300Hz | |
±3dB | ±3dB | ||
| |||
|
|
| |
Damping Factor | > 100 | > 100 | |
|
|
| |
Input Sensitivity Selection | Yes | Yes | |
Switch |
|
| |
|
|
| |
Input Sensitivity | |||
|
|
| |
Supply Voltage Range | 9 to 16V | 9 to 16V | |
|
|
|
Amplifier Section | HCCA25001 | HCCA50001 | |
| thermal, | thermal, | |
| DC offset, | DC offset, | |
Protection | short protection, | short protection, | |
| |||
| |||
|
|
| |
| Power 0/1 AWG, | Power 0/1 AWG, | |
Terminal Wire Gauge | Remote | Remote | |
Ground 0/1AWG, | Ground 0/1AWG, | ||
| |||
| Speaker 8 AWG | Speaker 8 AWG | |
|
|
| |
Input Impedance | 20 kΩ | 20 kΩ | |
|
|
| |
Fuse Size | 250 Amp | 500 Amp | |
|
|
| |
Dimensions (L x W x H) | 19.75" x 10.3" x 2.5 " | 24.75" x 10.3" x 2.5" | |
|
|
| |
Crossover Section |
|
| |
|
|
| |
High Pass | Continuously variable | Continuously variable | |
Crossover | |||
|
|
| |
Low Pass | Continuously variable | Continuously variable | |
Crossover | |||
|
|
| |
|
|
|
*Continuous 4Ω load 20Hz to 200Hz, < 1% THD, with input voltage at 14.4VDC. **Continuous 2Ω load 20Hz to 200Hz, < 1% THD, with input voltage at 14.4VDC.
© 2009 Directed Electronics. All rights reserved. | 6 |