Main Menu  (continued)

„„WB (WHITE BALANCE) adjustment mode

Select [VAR1] to [VAR3] for [COLOR TEMP.] in the [VIDEO CONFIG] menu to make WHITE BALANCE VAR1 to WHITE BALANCE VAR3 adjustments.

 

 

Underlined values indicate factory defaults.

Submenu

Setting

Description

COLOR TEMP.*10

USER 0 to 63

Selects the color temperature that will become the basis for adjustment.

 

D93

[USER 0 to 63] Adjustable settings 0 to 63

 

D65

(equivalent to a color temperature range of 3,000 K to 9,300 K)

 

D56

[D93] Equivalent to a color temperature of 9,300 K

 

 

[D65] Equivalent to a color temperature of 6,500K

 

 

[D56] Equivalent to a color temperature of 5,600 K

GAIN

Adjusts the GAIN elements

 

 

Press the rotary knob <PICTURE> to switch to RGB direct adjustment mode.

 

 

(This allows you to begin adjusting GAIN first.)

RED

0 to 1023

Displays the GAIN elements for RED. (For numerical value confirmation)

 

(A color temperature

 

GREEN

Displays the GAIN elements for GREEN. (For numerical value confirmation)

of [D65] is the factory

 

 

 

default value.)

 

BLUE

Displays the GAIN elements for BLUE. (For numerical value confirmation)

• This is a factory

 

 

 

default adjustment.

 

BIAS

Adjusts the BIAS elements

 

 

Press the rotary knob <PICTURE> to switch to RGB direct adjustment mode.

 

 

(This allows you to begin adjusting BIAS first.)

RED

- 512 to 511

Displays the BIAS elements for RED. (For numerical value confirmation)

GREEN

(Factory default setting:

Displays the BIAS elements for GREEN. (For numerical value confirmation)

BLUE

0)

Displays the BIAS elements for BLUE. (For numerical value confirmation)

 

RESET

Resets [GAIN] (RED/GREEN/BLUE) and [BIAS] (RED/GREEN/BLUE) set values

 

 

to color temperature values selected under [COLOR TEMP.].

*10Selecting [COLOR TEMP.] and pressing the rotary knob <PICTURE> after selecting an item, opens a confirmation screen. When you select [YES] and press the rotary knob <PICTURE> in this screen, the selected GAIN and BIAS values are reset to the selected color temperature values.

„„Direct adjustment mode

Press the rotary knob <PICTURE> when a [GAIN], [BIAS] or ZEBRA LEVEL item is selected in the WHITE BALANCE VAR (1 to 3) menu, to switch to the adjusting screen and use the rotary knob <PICTURE> to directly adjust the picture while checking the screen. When [WHITE BALANCE] and [ZEBRA LEVEL] are assigned to FUNCTION1 to FUNCTION5, you can access them using the <FUNCTION> buttons or the [FUNCTION] menu.

●WB● adjustment screen

 

995

1012

1023

0

0

0

RETURN RETURN

 

R.GAIN

G.GAIN

B.GAIN

R.BIAS

G.BIAS

B.BIAS

MENU EXIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

●ZEBRA● LEVEL adjustment screen

Operationprocedure

1.Turn the rotary knob <PICTURE> left or right to select an item to change and press the rotary knob <PICTURE>.

2.Turn the rotary knob <PICTURE> left or right to make changes.

• Press the rotary knob <PICTURE> to confirm the adjusted values.

<Note>

Press the <MENU> button in this adjusting screen to return to a

normal screen without a menu. *11

When the button is pressed before the values are confirmed, they will not be confirmed.

Pressing <RETURN/VOLUME> in this adjusting screen will return you to the previous cusor and screen.

When the <RETURN/VOLUME> is pressed before the values are confirmed, they will not be confirmed.

70%

85%

5%

100%

RETURN RETURN

[INT. ] MIN.

MAX. [EXT. ]

MIN.

MAX.

MENU EXIT

The above two screens cannot be recalled by using the <FUNCTION> button to access [RETURN].

*11A transition to the previous menu is also made if the monitor is left idle for 10 seconds. However, when called using a <FUNCTION> button, a normal screen without a menu reappears.

29