Main Menu  (continued)

INPUT SELECT

 

 

 

Underlined values indicate factory defaults.

Submenu

Setting

 

Description

VIDEO

AUTO

Used to select the format for VIDEO input.*1

 

NTSC

[AUTO]

Automatically selects NTSC or PAL.

 

PAL

[NTSC]

NTSC

 

 

[PAL]

PAL

NTSC SETUP

00

Selects NTSC setup level.

 

75

[00]

Select this when there is no setup signal.

 

 

[75]

Select this when using 7.5 % setup signals.

 

 

 

(The monitor internally adjusts the 7.5 % setup level to suit the black level)

DVI-I

DIGITAL

Selects DVI-I input mode.

 

ANALOG

[DIGITAL]

Selects digital input.

 

 

[ANALOG] Selects analog input.

DIGITAL

AUTO

Selects the DVI-I digital input mode.

 

VIDEO

[AUTO]

Selects the input mode automatically depending on the input format.

 

COMP.

[VIDEO]

Selects component input.

 

 

[COMP.]

Selects PC input.

ANALOG

YPBPR

Selects YPBPR (component) or RGB input mode when DVI-I is set to "ANALOG."

 

RGB-COMP.

[YPBPR]

Selects the YPBPR signal.

 

 

[RGB-COMP.] Selects the PC RGB signal.

COMPONENT

SMPTE

Selects the YPBPR (component) signal input level of DVI-I analog inputs.

LEVEL

B75

[SMPTE]

Signal level complies with SMPTE, and PB, PR are 0.7 V [p-p] at 100%

 

B00

 

chroma.

 

 

[B75]

Select this when connecting a Betacam or similar device with a setup function.

 

 

 

(The monitor internally adjusts the 7.5 % setup level to suit the black level)

 

 

[B00]

Select this when connecting a Betacam or similar device without a setup

 

 

 

function.

RGB-COMP.

Performs analog PC settings. (→ Below "RGB-COMP.")

*1 [AUTO] is the factory default, but select an appropriate format when there is risk that the input signal may be contaminated by outside noise.

„„RGB-COMP.

Selecting [ANALOG.] under [DVI-I] in the [INPUT SELECT] menu and selecting [RGB-COMP.] under [ANALOG] opens the following menu.

 

 

Underlined values indicate factory defaults.

Submenu

Setting

Description

H POSITION

0 to 60

Adjusts horizontal image display position in 2-clock units. *2

 

(Factory default setting:

 

 

30)

 

V POSITION

0 to 15

Adjusts vertical image display position. *2

 

(Factory default setting:

 

 

8)

 

PHASE

0 to 31

Adjusts the clock phase in 1/32 clock period increments. *2

 

(Factory default setting:

 

 

16)

 

CLOCK

700 to 2200

Adjusts the sampling clock in 2-clock units. *2 *4

 

(Factory default

 

 

setting*3)

 

RESET

 

Returns [H POSITION], [V-POSITION], [PHASE] and [CLOCK] settings in the

 

 

RGB-COMP. input compliant format to their factory defaults.

*2 Each compatible input format can be adjusted, but not when user data is loaded (→page 30 "SETUP LOAD") or saved (→page 30 "SETUP SAVE") .

*3 [CLOCK] factory default values

Format

CLOCK

Format

CLOCK

640×480 (60 Hz)

800

1280×768 (60 Hz)

1664

800×600 (60 Hz)

1056

1280×1024 (60 Hz)

1688

1024×768 (60 Hz)

1344

 

 

*4 This menu is disabled when the input signal format is 1920 x 1080 (60 Hz).