Image 19

[Reference]

command

mode

8

0

Error code

Individual readout of parameters

Received data

1

axis

0

8

Parameter No.

checksum

Transmitted data

3

axis

0

8

Parameter value L

H

Error code

checksum

 

bit7

6

5

4

3

2

1

0

0

: Normal

 

Command error

 

No. error

 

 

 

1

: Error

 

 

 

 

 

 

 

command

mode

8

1

Error code

Individual writing of parameters

Received data

3

axis

1

8

Parameter No.

Parameter value L

H

checksum

Transmitted data

1

axis

1

8

Error code

checksum

 

bit7

6

5

4

3

2

1

0

0

: Normal

Data error

Command error

 

No. error

 

 

 

1

: Error

 

 

 

 

 

 

 

This command just changes a parameter temporarily. If you wish to write to EEPROM, execute writing to EEPROM of parameter (mode=4)

Be sure to set 0 to unused parameters. Otherwise, data error will occur.

command

mode

8

4

Error code

Writing of parameters to EEPROM

Received data

0

axis

4

8

checksum

Transmitted data

1

axis

4

8

Error code

checksum

 

bit7

6

5

4

3

2

1

0

0

: Normal

Data error

Command error

 

 

 

Control LV

 

1

: Error

 

 

 

 

 

 

 

This command is used to write a set parameters to EEPROM.

Transmission data will be returned after completion of EEPROM writing.

Writing to EEPROM may take approx. 5 seconds max. (if all parameters are changed). When writing of parameters fails, data error will occur.

When control power supply LV is detected, control LV of error code will be returned, and parameter writing will be disabled.