Communications

command

mode

9

0

Error code

Readout of current alarm data

Received data

0

axis

0

9

checksum

Transmitted data

2

axis

0

9

Alarm No.

Error code

checksum

 

bit7

6

5

4

3

2

1

0

0

: Normal

 

Command error

 

 

 

 

 

1

: Error

 

 

 

 

 

 

 

Alarm No. is 0 when no alarm is generated.

(Refer to “Details of Protective Function” on Page 145.)

command

mode

9

1

Error code

Individual readout of alarm history

Received data

1

axis

1

9

History No.

checksum

Transmitted data

3

axis

1

9

History No.

Alarm No.

Error code

checksum

 

bit7

6

5

4

3

2

1

0

0

: Normal

 

Command error

 

No. error

 

 

 

1

: Error

 

 

 

 

 

 

 

History No.1 to No.14 indicate the 1st to 14th previous alarm history, respectively.

command

mode

9

2

Error code

Batch readout of alarm history

Received data

 

 

0

 

 

axis

 

 

2

 

9

 

checksum

 

1st previous

 

 

 

2nd previous

 

 

14th previous

Transmitted data

0Fh

axis

2

9

Alarm No.

Alarm No.

~

Alarm No.

Error code

checksum

 

bit7

6

5

4

3

2

1

0

0

: Normal

 

Command error

 

 

 

 

 

1

: Error

 

 

 

 

 

 

 

The command is used to read 14 previous alarm events.