Appendix
Technical Information
PJLink protocol
The network function of the projector supports PJLink class 1, and the PJLink protocol can be used to perform projector setting and projector status query operations from a computer.
JJControl commands
The following table lists the PJLink protocol commands that can be used to control the projector.
Command | Control details |
|
|
| Notes |
| |
|
| Parameters |
|
|
|
| |
POWR | Power supply control | 0 = Standby |
|
|
|
| |
|
| 1 = Power ON |
|
|
|
| |
|
| Parameters |
|
|
|
| |
POWR ? | Power supply status query | 0 = Standby | 1 = Power ON |
| |||
|
| 2 = | 3 = | ||||
INPT | Input selection | Parameters |
|
|
|
| |
|
| 11 = RGB 1 12 = RGB 2 | 13 = Scart | 21 = VIDEO 1 | |||
INPT ? | Input selection query | 22 = VIDEO 2 | 23 = | ||||
25 = COMPONENT 2 | 31 = DIGITAL 1 | 32 = DIGITAL 2 | |||||
|
| ||||||
|
| 33 = DIGITAL 3 | 46 = INPUT 1 47 = INPUT 2 48 = INPUT 3 | ||||
AVMT | AV MUTE control | Parameters |
|
|
|
| |
AVMT ? | AV MUTE status query | 30 = AV MUTE mode off |
|
| |||
31 = AV MUTE mode on |
|
| |||||
|
|
|
| ||||
|
| Parameters |
|
|
|
| |
|
| 1st byte : Indicates fan errors, range 0 – 2 | |||||
|
| 2nd byte : Indicates lamp errors, range 0 – 2 | |||||
|
| 3rd byte : Indicates temperature errors, range 0 – 2 | |||||
ERST ? | Error status query | 4th byte : Fixed at 0 |
|
|
| ||
|
| 5th byte : Indicates filter errors, range 0 – 2 | |||||
|
| 6th byte : Indicates other errors, range 0 – 2 | |||||
|
| Definitions for each value from 0 to 2 are as follows. | |||||
|
| 0 = No error known | 1 = Warning | 2 = Error | |||
|
| Parameters |
|
|
|
| |
LAMP ? | Lamp status query | 1st digits (1 – 5 digits) : Lamp cumulative operating time | |||||
|
| 2nd digit : 0 = Lamp off, 1 = Lamp on |
| ||||
INST ? | Input selection list query | The followings are returned as parameters. | |||||
“ 11 12 13 21 22 23 24 25 31 32 33 46 47 48” | |||||||
|
| ||||||
NAME ? | Projector name query | The name set for [Projector name] in [Network] is returned. | |||||
INF1 ? | Manufacturer name query | “Panasonic” is returned. |
|
| |||
INF2 ? | Model name query | Answer the model name with either “EZ570”, “EW630”, “EW530”, | |||||
“EX600”, or “EX500”. |
|
|
| ||||
|
|
|
|
| |||
INF0 ? | Other information query | Information such as version number is returned. | |||||
CLSS ? | Class information query | “1” is returned. |
|
|
|
|
JJPJLink security authorization
When using PJLink with security authorization, either of the password set for administrator privileges and the password set for user privileges with Web browser control can be used as the password for PJLink (Æpage 86). When using PJLink without security authorization, set use without the password for administrator privileges and the password for user privileges of Web browser control.
For specifications regarding PJLink, refer to the Japan Business Machine and Information System Industries Association website.
100 - ENGLISH