Network

JJError information page

If [Error (Detail)] is displayed in the self-diagnosis information display column on the [Projector status] screen, click the part to display the details of the error.

Depending on the nature of the error, the projector may be placed in the standby mode for its own protection.

OK:

Normal operation

FAILED : Occurrence of trouble

WARNING: Warning

 

When [FAILED] has appeared for an item

 

 

Parameter

Description

MAIN CPU BUS

Trouble has occurred in the microcomputer circuitry. Consult your dealer.

FAN

Trouble has occurred in the fan or its drive circuit. Consult your dealer.

 

Intake air temperature is high. It could be because it is used in an environment of high

INTAKE AIR TEMPERATURE

temperature such as close to a heating device, etc., the air intake is blocked, or the air

 

filter is clogged.

 

 

AROUND LAMP TEMPERATURE

The temperature around the lamp is too high. Exhaust may be blocked, or [Fan control]

mode may be set wrong. See [Fan control] of the Functional Manual. (Æpage 65)

 

OPTICS MODULE TEMPERATURE

Optics module temperature is high. The exhaust air port maybe blocked or the air filter

is clogged.

 

LAMP REMAIN TIME

The lamp runtime has exceeded the prescribed cumulative time, and it is now time to

replace the lamp.

 

 

 

LAMP STATUS

The lamp has failed to light.

Wait a short while for the lamp to cool off, and then turn on the power.

 

APERTURE(CONTRAST-SHUTTER)

Trouble has occurred in the contrast shutter circuitry. Consult your dealer.

SHUTTER

There is a problem with shutter.

AIR FILTER

There is a problem with the air filter unit.

FILTER UNIT

The air filter unit is not installed.

JJNetwork status page

Displays the current configuration information of the network.

Displays the configuration details of wired LAN.

Settings

ENGLISH - 77