About indicator status
JJWhen there is a problem with internal temperature
The status of the indicator is displayed with the following symbols. : Off, : On, : Flashing, : Off or On or Flashing
|
| Indicators |
|
|
|
|
|
<ON(G)/ | <TEMP> |
| <SHUTTER/ | <LAMP> | Status of the projector | ||
STANDBY(R)> | <FILTER> | ||||||
Green/Red/ | Red | Orange | AV MUTE> | Orange |
|
|
|
Blue |
|
|
| ||||
Orange |
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
| If the temperature within the projector becomes | ||
// | *1 | *2 | *2 | *2 | too high, the temperature indicator <TEMP> will | ||
|
|
|
|
| start to flash slowly. |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| If the temperature within the projector becomes | ||
|
|
|
|
| even higher, the temperature indicator <TEMP> | ||
|
|
|
|
| will flash faster, the power indicator <ON(G)/ | ||
|
|
|
|
| STANDBY(R)> will turn off, and the projector | ||
|
|
|
|
| will turn off automatically. |
| |
|
|
|
|
| The projector will not turn back on even | ||
|
|
|
|
| when pressing the <POWER ON> button on | ||
//*3 | *4 | *2 | *2 | *2 | the remote control or the < |
| > button on |
the side control. When the projector returns | |||||||
|
|
|
|
| to the normal operating temperature, the | ||
|
|
|
|
| standby indicator <ON(G)/STANDBY(R)> will | ||
|
|
|
|
| change to on. The projector will turn back on | ||
|
|
|
|
| when pressing the <POWER ON> button on | ||
|
|
|
|
| the remote control or the < |
| > button on |
|
|
|
|
| the side control. (The temperature indicator | ||
|
|
|
|
| <TEMP> will remain flashing.) Check the air | ||
|
|
|
|
| filter. |
|
The projector has cooled inside, and returned to operating temperature. Pressing the <POWER ON> button on the remote control
// | *4 | *1 | *1 | *1 | or the < |
|
|
| > button on the side control will |
|
| ||||||||
|
|
|
|
| make the temperature indicator <TEMP> stop | ||||
|
|
|
|
| flashing and operate the projector. Check the | ||||
|
|
|
|
| air filter. |
|
|
*1: The indicator will flash in approximately
*2: The indicator will change according to different conditions, regardless of the status of other indicators.
*3: The indicator will flash in approximately
*4: The indicator will flash in approximately
Maintenance
90 - ENGLISH