Technical Information

JJWhen WEB Control administrator rights password is not set (Non-protect mode)

zzConnection method

1111Obtain the IP address and port number (Initial set value = 1 024) of the projector and make a request for connection to the projector.

Acquire the IP address from the menu screen of the projector, and the port number from the WEB control page.

IP address : Obtain from MAIN MENU → [Network] → [Network status]

Port No. : Acquire from the WEB control “Detailed set up” → “Command port set up” page

2222There is a response from the projector.

Response data

Data section

Blank

Mode

Termination symbol

“NTCONTROL”

‘  ’

‘0’

(CR)

(ASCII string)

0x20

0x30

0x0d

9 bytes

1 byte

1 byte

1 byte

Mode : 0 = Non-protect mode

 

 

 

zz

 

 

 

 

Command transmission method

 

 

Transmit by the following command format.

 

 

Transmitted data

 

 

 

 

Header

 

 

Data section

Termination symbol

‘0’

 

‘0’

 

Control command

(CR)

0x30

 

0x30

 

(ASCII string)

0x0d

1 byte

 

1 byte

 

Undefined length

1 byte

Receive data

 

 

 

 

Header

 

 

Data section

Termination symbol

‘0’

 

‘0’

 

Control command

(CR)

0x30

 

0x30

 

(ASCII string)

0x0d

1 byte

 

1 byte

 

Undefined length

1 byte

Receive data

 

 

 

 

 

 

Error message

 

Termination symbol

“ERR1”

Undefined control command

 

“ERR2”

Out of parameter range

 

 

“ERR3”

Busy state or no-acceptable period

(CR)

“ERR4”

Timeout or no-acceptable period

0x0d

“ERR5”

Wrong data length

 

 

“ERRA”

Password mismatch

 

 

 

 

4 bytes

 

1 byte

Appendix

102 - ENGLISH