Technical Information
JJWhen WEB Control administrator rights password is not set
zzConnection method
1111Obtain the IP address and port number (Initial set value = 1 024) of the projector and make a request for connection to the projector.
Acquire the IP address from the menu screen of the projector, and the port number from the WEB control page.
IP address : Obtain from MAIN MENU → [Network] → [Network status]
Port No. : Acquire from the WEB control “Detailed set up” → “Command port set up” page
2222There is a response from the projector.
Response data
Data section | Blank | Mode | Termination symbol |
“NTCONTROL” | ‘ ’ | ‘0’ | (CR) |
(ASCII string) | 0x20 | 0x30 | 0x0d |
9 bytes | 1 byte | 1 byte | 1 byte |
Mode : 0 = |
|
|
|
zz |
|
|
|
| |
Command transmission method |
|
| |||
Transmit by the following command format. |
|
| |||
Transmitted data |
|
|
|
| |
Header |
|
| Data section | Termination symbol | |
‘0’ |
| ‘0’ |
| Control command | (CR) |
0x30 |
| 0x30 |
| (ASCII string) | 0x0d |
1 byte |
| 1 byte |
| Undefined length | 1 byte |
Receive data |
|
|
|
| |
Header |
|
| Data section | Termination symbol | |
‘0’ |
| ‘0’ |
| Control command | (CR) |
0x30 |
| 0x30 |
| (ASCII string) | 0x0d |
1 byte |
| 1 byte |
| Undefined length | 1 byte |
Receive data |
|
|
|
| |
|
| Error message |
| Termination symbol | |
“ERR1” | Undefined control command |
| |||
“ERR2” | Out of parameter range |
|
| ||
“ERR3” | Busy state or | (CR) | |||
“ERR4” | Timeout or | 0x0d | |||
“ERR5” | Wrong data length |
|
| ||
“ERRA” | Password mismatch |
|
| ||
|
| 4 bytes |
| 1 byte |
Appendix
102 - ENGLISH