■Connection with the Uninterrupted Power Supply (UPS)

Connection with the Uninterrupted Power Supply (UPS)

The figure shows an example of how to connect a UPS as protection against power failures.

When a power failure detect input is received from the UPS, the disk recorder's power failure process starts to process this signal to turn off its power supply.

When the power failure process is completed, the disk recorder outputs a signal to the UPS.

When the UPS receives the completion signal from the disk recorder, the disk recorder's power is turned off

Power Failure Process

UPS Shut Down

Completion Output

Power Failure Detect Input

Line Fail signal

(Normally Open)

Disk Recorder

Ground

WJ-HD500A

 

(19)

(17)

(16)

CONTROL

 

Common

CBefore connecting the UPS, refer to the manual of your UPS.

Uninterrupted

Power Supply

to AC outlet

Power Cable

Connection with CONTROL output

Signal outputs (Pins #1-6, 18) can be used to connect alarm devices such as a buzzer or lamp to inform you of the opera- tion status by sounding a buzzer or lighting a lamp when a signal is output.

The figure below shows an example of how to connect an alarm output (Pin #6) to warn of low remaining HDD capacity.

 

(Remaining HDD Capacity Alarm Output)

(6)

(15) Ground

Alarm Device

Relay, etc.

CONTROL Input/Output