Panasonic WJ-HD500A Parity Check, Stop Bit, Wait Time, Alarm Data, Input Camera Number Setup

Models: WJ-HD500A

1 102
Download 102 pages 58.08 Kb
Page 67
Image 67
●Parity Check

Parity Check

This item lets you set the parity bit for RS-485 communica- tion.

1.Move the cursor to the PARITY CHECK parameter by pressing the D or C button.

2.Select NONE, EVEN or ODD for parity check by press- ing the + or - button.

The factory default setting is NONE.

Stop Bit

This item lets you set the number of stop bits for RS-485 communication.

1.Move the cursor to the STOP BIT parameter by press- ing the D or C button.

2.Select either 1 or 2 for the number of stop bits by press- ing the + or - button.

The factory default setting is 1 bit.

Wait Time

This item lets you set the waiting time in milli-seconds (ms) to retry after confirming that no data is received from the controller for RS-485 communication.

1.Move the cursor to the WAIT TIME parameter by press- ing the D or C button.

2.Select OFF, 100, 200, 400, or 1 000 ms for the wait time by pressing the + or - button.

When no transmission is needed, select OFF.

The factory default setting is OFF (no retry).

Alarm Data

This item lets you enable or disable notification of the alarm data received to the controller (Unit Number 1).

1.Move the cursor to the ALARM DATA parameter by pressing the D or C button.

2.Select the desired mode by pressing the + or - but- ton.

OFF: Select this parameter if the system controller is not connected to the system.

0S: Each time an alarm is received, it is transmitted to the system controller.

1S: The received alarm is stored for 1 second, and that data is sent to the system controller.

5S: The received alarm is stored for 5 seconds, and that data is sent to the system controller.

The factory default setting is 1S.

Input (Camera) Number Setup

This item lets you assign numbers for the input from the system cameras for RS-485 communication.

1.Move the cursor to CAMERA NUMBER SETUP by pressing the D or C button, then press the SET button. The CAMERA NUMBER SETUP table shown below appears on the monitor screen.

8-1-1 CAMERA NUMBER SETUP

 

CAM-PORT CAM NO.

CAM-PORT CAM NO.

1

001

9

009

2

002

10

010

3

003

11

011

4

004

12

012

5

005

13

013

6

006

14

014

7

007

15

015

8

008

16

016

2.Move the cursor to the input (CAM-PORT) parameter to edit by pressing the D, C, A or B button, then select a camera number by pressing the + or - button.

---:No assignment.

001 - 128: Assigns the selected number.

Note: Make sure not to assign the same number to more than one system camera for RS-485 communi- cation.

3.Repeat the above procedure to edit other input para- meters.

4.After completing the settings, press the SETUP/ESC button to return to the previous setup menu.