ALARM SETUP

1.Move the cursor to ALARM SETUP in the WJ-HD500 SETUP menu by pressing the D or C button, then press the SET button.

The ALARM SETUP menu shown below appears on the monitor screen.

6 ALARM SETUP

 

TERMINAL TRIGGER SETUP

 

AUTO RESET

 

OFF

ALARM

OUTPUT

2S

ALARM

BUZZER

2S

VIDEO

LOSS

 

ON

VIDEO

MOTION DETECTION

OFF

VMD

AREA

SETUP

 

ALARM

MODE

MULTI OUTPUT

SPOT

 

 

SPOT OUTPUT

SPOT

2.Select an item or item parameter in the menu by press- ing the D or C button.

3.To return to the previous WJ-HD500 SETUP menu, press the SETUP/ESC button.

Alarm Port Setting

This item lets you designate the alarm input from the ALARM port located on the rear of the Disk Recorder.

1.Move the cursor to TERMINAL TRIGGER SETUP in the ALARM SETUP menu by pressing the D or C button, then press the SET button.

The table shown below appears on the monitor screen.

6-1 TERMINAL TRIGGER SETUP

ALM CAM INPUT

ALM CAM INPUT

1CH

1

N.O

9CH

9

N.O

2CH

2

N.O

10CH

10

N.O

3CH

3

N.O

11CH

11

N.O

4CH

4

N.O

12CH

12

N.O

5CH

5

N.O

13CH

13

N.O

6CH

6

N.O

14CH

14

N.O

7CH

7

N.O

15CH

15

N.O

8CH

8

N.O

16CH

16

N.O

2.Move the cursor to the input channel editing area by pressing the A, B, D or C button.

3.Select a camera number (1 - 16) corresponding to the input for the CAM editing area by pressing the + or - button.

4.Move the cursor to the INPUT editing area by pressing the B button, then select the type of contact to meet the system requirement by pressing the + or - but- ton.

N.O: Accepts alarm input from Normally Open con- tacts.

N.C: Accepts alarm input from Normally Closed con- tacts.

The factory default setting is N.O.

5.Repeat the above steps 2 to 4 to designate the other input channels.

6.When satisfied with all of the above steps, press the SETUP/ESC button to return to the previous ALARM SETUP menu.

Alarm Auto Reset Setting

This item lets you select the duration the Disk Recorder retains the alarm mode before resetting automatically.

1.Move the cursor to the AUTO RESET parameter in the ALARM SETUP menu by pressing the D or C button.

2.Select the desired duration by pressing the + or - button.

OFF: Disables auto reset.

1S - 30S, 40S, 50S, 1M - 5M: Selects an alarm duration between 1 second and 5 minutes.

The factory default setting is OFF.

Alarm Output Setting

This item lets you select the output duration of the alarm signal from the ALARM port.

1.Move the cursor to the ALARM OUTPUT parameter in the ALARM SETUP menu by pressing the D or C but- ton.

2.Select the desired duration by pressing the + or - button.

OFF: Disables alarm output, regardless of an incoming alarm.

1S - 30S, 40S, 50S, 1M - 5M: Selects an alarm duration between 1 second and 5 minutes.

62

Page 60
Image 60