External Program Timer

The internal timer can be changed to the specified timer previously programmed by the input from the external timer. This function is enabled, when a contact is connect- ed with pin 22 of the ALARM port.

This item lets you enable or disable the external timer for recording.

1.Move the cursor to the EXT REC MODE parameter in the TIMER REC SETUP menu by pressing the D or C button.

2.Select the desired program to be changed by pressing the + or - button.

PROG1 - 4: Selects a timer assigned program number.

---:Disables the external program timer.

The factory default setting is ---.

3.Press the SET button to display the assigned program number menu previously programmed.

If the program number menu has not been edited previ- ously, edit the assigned program number menu as described before.

4.Press the SETUP/ESC button to return to the previous setup menu.

Time Lapse Recording (Internal Timer)

These items let you set the recording parameters for Time Lapse Recording assigned in the program number menu.

(Continued from Program Timer)

1.Select the recording mode T/L in the program number menu by pressing the + or - button, then press the SET button.

The selected Time Lapse Recording menu shown below appears on the monitor screen.

3-1-1-1 PROG1-NO1-G1 REC SETUP

T/L(TIME LAPSE)

TIMER

REC MODE

SF- 24H

REC

RATE

7.5FPS

QUALITY

SUPER FINE

TRIGGER ACTION

REC+ALM

EVENT REC MODE

SF- 24H

REC

RATE(MAX)

7.5FPS

REC

QUALITY

SUPER FINE

DURATION

10S

DYNAMIC REC

OFF

REC

RATE(BASE)

1FPS

AUTO COPY

OFF

2.Move the cursor to the TIMER REC MODE parameter in the menu by pressing the D or C button.

3.Select the recording time mode to be set by pressing the + or - button.

OFF: Disables normal recording and enables only alarm recording.

SF-✽✽H or SF-A*✽✽H:Selects the recording time mode in enhanced fine quality.

FQ-✽✽H or FQ-A*✽✽H:Selects the recording time mode in fine quality.

NQ-✽✽H or NQ-A*✽✽H:Selects the recording time mode in normal quality.

EX-✽✽H or EX-A*✽✽H:Selects the recording time mode in extended quality.

SP or SP-A*:Freely selectable

✽✽indicates the hours for recording time mode:

2, 12, 18, 24, 48, 72, 96, 120, 180, 240, 360, 480, 720, 960, 1200, 1440, 2160, 2880, 3600, 4320, 6480, 8640

(parameter A* indicates recording with audio)

When the parameter SF/FQ/NQ/EX is selected for recording time, the recording rate and quality are auto- matically set according to the selected recording time.

Note: It may not be possible to set the recording time, depending on the remaining storage capacity of the hard disk.

The factory default setting is SF-24H.

4.If the parameter SP is selected for recording time, move the cursor to the REC RATE parameter by pressing the D or C button, then select a recording rate by pressing the + or - button.

1 - 60FPS: Records the selected number of freeze images every second.

0.5FPS: Records a freeze image every 2 seconds.

0.4FPS: Records a freeze image every 2.5 seconds.

0.3FPS: Records a freeze image every 3.3 seconds.

0.2FPS: Records a freeze image every 5 seconds.

0.1FPS: Records a freeze image every 10 seconds.

Notes:

The maximum recording rate depends on the selected parameters in the COMMON SETUP menu as shown in the table.

FIELD/FRAME

CAMERA GENLOCK

REC RATE

FIELD

ON

60FPS

 

OFF

30FPS

FRAME 3DIM

ON

10FPS

ON

OFF

10FPS

FRAME 3DIM

ON

30FPS

OFF

OFF

15FPS

52