ALARM

$7Alarm Port (ALARM)

This port accepts the alarm input from the associated alarm sensors through either Normally Open or Normally Closed contacts.

The pin assignment of the port is shown below.

13

1

 

25

ALARM

14

 

 

 

 

 

 

 

 

Pin

Designation

 

Pin

Designation

No.

 

No.

 

 

 

1

Alarm Input 1

 

14

Ground

 

 

 

 

 

2

Alarm Input 2

 

15

Alarm Input 5

 

 

 

 

 

3

Alarm Input 3

 

16

Alarm Input 6

 

 

 

 

 

4

Alarm Input 4

 

17

Alarm Input 7

 

 

 

 

5

Sequence Timing Input

18

Alarm Input 8

 

 

 

 

 

6

Alarm Reset Output

 

19

Alarm Input 9

 

 

 

 

 

7

Ground

 

20

Ground

 

 

 

 

 

8

Alarm Recover Input

 

21

+5 V Output (0.2 A)

 

 

 

 

 

9

Alarm Output

 

22

Recording Timer Select

 

Input

 

 

 

 

 

10

Alarm Input 10

 

23

Alarm Input 14

 

 

 

 

 

11

Alarm Input 11

 

24

Alarm Input 15

 

 

 

 

 

12

Alarm Input 12

 

25

Alarm Input 16

 

 

 

 

 

13

Alarm Input 13

 

 

 

 

 

 

 

 

$8Copy Port (COPY)

For connecting the optional DVD Extension Unit.

$9Mode Selector (MODE)

Selects data termination for PSData system expansion.

%0Data Port (DATA)

Exchanges control data with the external device with PSData (Panasonic Security Data) mode.

%1Remote Port [REMOTE (WV-CU50)]

This port is provided for controlling the Disk Recorder with the optional WV-CU50 Remote Controller.

To connect to the controller, use a 6-conductor modular cable supplied as an accessory with the controller.

%2Gen-lock Output Connector (GEN-LOCK OUT)

This connector is used to connect an external system for synchronization.

To record images at maximum recording rate, for exam- ple 60 fps, connect this output to the cameras to syn- chronize the system.

%3Serial Port (SERIAL)

For connecting a Personal Computer.

%4Signal Ground Terminal (SIGNAL GND)

%510/100BASE-T Port (Optional)

An optional Network Board can be installed in the Disk Recorder.

This port is used to exchange control data with Ethernet via an Ethernet Hub.

%6Cooling Fan

Prevents the temperature of the Recorder from rising. Do not block the ventilation opening on the cover.

%7AC Inlet Socket (AC IN)

Plug the power cord (supplied as a standard accesso- ry) into this socket and connect it to an AC outlet.

%8Power Switch (POWER ON/OFF)

This switch turns the power of the Disk Recorder on and off.

%9Video Output Connectors (VIDEO OUT 1 - 16)

The video signal connected to the Video Input Connector (VIDEO IN) is looped through these connec- tors with an automatic 75 termination.

^0Video Input Connectors (VIDEO IN 1 - 16)

These connectors accept either a color or B/W compos- ite video signal from the camera.

9