COMMUNICATION SETUP

COMMUNICATION SETUP

The procedures described below let you set the parame- ters for the Disk Recorder to communicate with external devices.

1.Move the cursor to COMMUNICATION SETUP in the WJ-HD500 SETUP menu by pressing the C or D but- ton, then press the SET button.

The COMMUNICATION SETUP menu shown below appears on the monitor screen.

8 COMMUNICATION SETUP

PS•Data SETUP

RS232C SETUP

NETWORK SETUP

IP ADDRESS ●Unit Address Setting 192.168.000.010

NETMASK ■PS • Data Setup 255.255.255.000

GATEWAY ●Baud Rate 192.168.000.001

2.Select an item or item parameter in the menu by press- ing the D or C button.

3.To return to the previous setup menu, press the SETUP/ESC button.

Unit Address Setting

This item lets you set the unit address of the Disk Recorder in the system for RS-485 communication.

1.Move the cursor to the UNIT ADDRESS parameter by pressing the D or C button.

2.Select the unit address number to be used for RS-485 communication by pressing the + or - button.

Select a parameter value between 001 and 099.

The factory default setting is 001.

2.Select an item or item parameter in the menu by press- ing the D or C button.

3.To return to the previous WJ-HD500 SETUP menu, press the SETUP/ESC button.

PS Data Setup

These items let you set the parameters for communication between the System Controllers and the Disk Recorders when the system is controlled with the PS Data mode (Panasonic Security Data).

1.Move the cursor to PS Data SETUP in the COMMUNI- CATION SETUP menu by pressing the C or D button, then press the SET button.

The PS Data SETUP menu shown below appears on the monitor screen.

8-1 PS•Data SETUP

UNIT ADDRESS

001

BAUD RATE

9600

DATA BIT

8

PARITY CHECK

NONE

STOP BIT

1

WAIT TIME

OFF

ALARM DATA

1S

CAMERA NUMBER SETUP

Baud Rate

This item lets you set the transmission speed for RS-485 communication.

1.Move the cursor to the BAUD RATE parameter by pressing the D or C button.

2.Select the desired transmission speed shown below by pressing the + or - button.

2 400 4 800 9 600 19 200 38 400

The factory default setting is 9 600 bps.

Data Bit

This item lets you set the number of data bits for RS-485 communication.

The factory default setting is 8 bits and fixed.