Connection with PS·Data systems

This is an example of connection when the unit is used together with the PS·Data devices.

If a connected system controller is PS·Data compatible, it is possible to operate this unit or connected devices using the sys- tem controller.

Use the RS485 cable provided with the system controller.

Important:

Terminate both devices on both ends of the connection. Refer to the respective operating instructions for the descriptions of how to terminate. Termination of this unit can be set with the mode selection DIP switch on the rear panel. (See page 47.)

When connecting a PS·Data compatible device, it is necessary to set each item of "PS.Data Setup" of "Communication Setup" according to the system configuration.

The following are available PS·Data compatible devices.

System controller: WV-CU650 (Ver 2.10 or later)

Data multiplex unit: WJ-MP204

Matrix switcher: WJ-SX650 (Ver. 3.00 or later)

(Any other PS·Data compatible devices are not to be connected.)

When connecting a single unit with a controller

Controller

Termination: ON

Unit Address: 1

A B

1

2

3

4

5

6

7

8

9

 

0

 

RS485 cable

(provided with the controller)

 

 

 

 

 

 

 

 

ON

 

 

 

 

Mode selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIP switches

 

 

 

 

 

 

 

 

 

 

1

2

 

 

 

 

 

 

 

 

 

RS485(CAMERA)

 

 

 

 

 

 

 

 

5

3

1

 

AUX IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER

 

 

 

SERIAL

 

 

 

 

 

 

 

AUDIO IN/ALARM OUT

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

1 2

 

 

 

 

 

 

 

6

4

2

AUDIO OUT MONITOR1

 

MONITOR2

 

DATA

MODE 10/100BASE-T

 

COPY1

 

 

ALARM IN/CONTOROL

 

 

 

AUDIO IN

SIGNAL GND

IN

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC IN

 

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

 

 

 

 

 

 

 

 

VIDEO

 

 

 

 

 

 

 

 

This unit

"PS.Data Setup" of "Communication Setup" on the Setup Menu

Unit Address (System): 1

Unit Address (Controller): 2

44