Panasonic WJ-RT416V manual RS485 Camera port, Audio IN/ALARM OUT terminal

Models: WJ-RT416 WJ-RT416V

1 80
Download 80 pages 18.29 Kb
Page 49
Image 49

RS485 (CAMERA) port

When connecting an RS485 camera, connect it to the RS485 (CAMERA) port on the rear of the recorder.

RS485(CAMERA)

Signal TA TB

RA RB Signal

GND

 

 

 

 

GND

OUT

 

IN

Block diagram

RA

RB

TA

TB

AUDIO IN/ALARM OUT terminal

!3 q

Control circuit

AUDIO IN/ALARM OUT

@5 !4

Normally close output

Common output

Normally open output

Internal block diagram

In normal

At an alarm

state

occurrence

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin No.

Signal

Operation

Remark

q

Audio input CH7

Audio input (CH7)

–10 dBv 51 k, unbalanced

 

 

 

 

w

Audio input CH8

Audio input (CH8)

–10 dBv 51 k, unbalanced

 

 

 

 

e

Audio input CH9

Audio input (CH9)

–10 dBv 51 k, unbalanced

 

 

 

 

r

Audio input CH10

Audio input (CH10)

–10 dBv 51 k, unbalanced

 

 

 

 

t

Audio input CH11

Audio input (CH11)

–10 dBv 51 k, unbalanced

 

 

 

 

y

Audio input CH12

Audio input (CH12)

–10 dBv 51 k, unbalanced

 

 

 

 

u

Audio input CH13

Audio input (CH13)

–10 dBv 51 k, unbalanced

 

 

 

 

i

Audio input CH14

Audio input (CH14)

–10 dBv 51 k, unbalanced

 

 

 

 

o

Audio input CH15

Audio input (CH15)

–10 dBv 51 k, unbalanced

 

 

 

 

!0

Audio input CH16

Audio input (CH16)

–10 dBv 51 k, unbalanced

 

 

 

 

!1

(Signal GND)

 

 

 

 

 

 

!2

Alarm 1 Output (COMMON)

Common output 1

1 A, 30 V DC max.

 

 

 

 

!3

Alarm 1 Output (NO)

Output 1, Normally open-collector

1 A, 30 V DC max.

 

 

 

 

!4

Alarm 1 Output (NC)

Output 1, Normally closed-collector

1 A, 30 V DC max.

 

 

 

 

!5

Alarm 2 Output (COMMON)

Common output 2

1 A, 30 V DC max.

 

 

 

 

!6

Alarm 2 Output (NO)

Output 2, Normally open-collector

1 A, 30 V DC max.

 

 

 

 

!7

Alarm 2 Output (NC)

Output 2, Normally closed-collector

1 A, 30 V DC max.

 

 

 

 

!8

Alarm 3 Output (COMMON)

Common output 3

1 A, 30 V DC max.

 

 

 

 

!9

Alarm 3 Output (NO)

Output 3, Normally open-collector

1 A, 30 V DC max.

 

 

 

 

@0

Alarm 3 Output (NC)

Output 3, Normally closed-collector

1 A, 30 V DC max.

 

 

 

 

@1

Alarm 4 Output (COMMON)

Common output 4

1 A, 30 V DC max.

 

 

 

 

@2

Alarm 4 Output (NO)

Output 4, Normally open-collector

1 A, 30 V DC max.

 

 

 

 

@3

Alarm 4 Output (NC)

Output 4, Normally closed-collector

1 A, 30 V DC max.

 

 

 

 

@4

(Signal GND)

 

 

 

 

 

 

@5

+12 V

+12 V output

800 mA max.

 

 

 

 

49

Page 49
Image 49